Fire Safety Regulations For Flats
In this guide, we’ll cover the fire safety regulations for flats in England and steps to mitigate the risk of fires in residential properties, such as blocks of flats.
Here at ELECSEC, we’ve been working in fire safety for many years, with over 50 years of combined experience in installing fire alarm in Bristol.
Key Takeaways On Fire Safety Regulations For Flats
- Landlords and building owners are legally responsible for fire safety in all communal areas, and must conduct regular Fire Risk Assessments, maintain escape routes, and keep fire safety equipment in working order
- Smoke alarms must be fitted on every floor and carbon monoxide detectors in any room with a fixed combustion appliance, both tested at the start of each tenancy. All electrical installations must be inspected at least every five years.
- Buildings over 11 metres have additional fire door inspection duties, and high-rise buildings (18 metres or 7 storeys and above) face further requirements including secure information boxes, wayfinding signage, and monthly testing of firefighting systems.
- From April 2024, all newly built residential buildings over 18 metres must include a second staircase. This does not apply retrospectively to existing buildings.
- From 6 April 2026, Responsible Persons of qualifying buildings must produce Personal Emergency Evacuation Plans (PEEPs) for any resident who cannot safely self-evacuate, and share this information with the local Fire and Rescue Service.
- All fire safety materials must now be assessed under BS EN 13501 following the withdrawal of BS 476, and building managers should follow BS 9991:2024 as the recognised best practice standard for residential fire safety.
What Fire Safety Concerns Do Flats Carry?
Due to the construction of flats, fires start in a single flat and then spread throughout the building.
Therefore, fire safety measures are vitally important in every flat and in the shared spaces in the block to reduce the risk of a fire spreading and causing widespread damage.
Often, widespread fires can be avoided or mitigated by effective fire safety measures.
What Responsibilities Do Landlords and Building Owners Have?
Landlords and building owners are legally responsible for ensuring that the communal areas of properties are safe, structurally sound and habitable. Therefore, they are legally responsible for ensuring fire safety.
The core duties of a building owner or landlord are to:
- Conduct regular Fire Risk Assessments (FRAs),
- Maintain communal escape routes,
- Install working smoke and carbon monoxide detectors,
- Ensure internal furnishings and gas/electrical systems meet strict safety requirements.
Having a proactive, efficient response team can help the police to apprehend intruders.
More specifically;
Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must undertake and regularly review a fire risk assessment of parts of the building that are not in private homes. They must also put in place and maintain adequate and appropriate fire precautions to reduce the risk of fire in those areas and ensure that suitable escape routes are available, kept clear and maintained.
The Building Safety Act 2022 introduced further significant duties for those responsible for residential buildings. It established the Building Safety Regulator (BSR) and created the concept of an ‘Accountable Person’ for higher-risk buildings (buildings with a top floor over 11 metres). Accountable Persons must register their buildings with the BSR, assess and manage building safety risks, and maintain a ‘golden thread’ of up-to-date information about the building. The Act also gave local authorities and the BSR greater enforcement authority, including the ability to prosecute those who fail to comply.
Various laws place additional responsibilities on landlords to ensure fire safety within their properties:
- At least one smoke alarm must be fitted on every floor of the flat used as living accommodation, and they must be tested on the first day of each new tenancy.
- Carbon monoxide detectors must be fitted in any room used as living accommodation that contains any fixed combustion appliance (which includes gas boilers and oil heaters). These must also be tested on the first day of each new tenancy.
- All gas and electric appliances must be safe and maintained.
- All electrical installations must be inspected and tested by a qualified and competent person, at least every 5 years.
- All furniture and furnishings supplied must be compliant with the Furniture and Furnishings (Fire Safety) Regulations 1988.
A fire risk assessment is a good way to ensure that your property is fully compliant with the latest regulations, particularly as various regulations have been introduced over the last few years.
For multi-occupied residential buildings over 11 metres, the Responsible Person must legally conduct quarterly inspections on all fire doors in the communal and common areas, as well as annual checks on all flat entrance doors, including inspecting self-closers, seals, and overall door integrity.
For high-rise buildings 18 metres or 7 storeys and over, under the Fire Safety (England) Regulations, secure information boxes must be installed on-site containing hard copies of building floor plans and contact details for the Fire and Rescue service. Wayfinding signage is also required in the form of clear, high-visibility floor and flat number signage in all stairwells and corridors to assist firefighters. It’s also important that mandatory monthly testing is carried out on all firefighting lifts, dry/wet risers, and smoke detector systems. Any faults lasting over 24 hours must be reported immediately to the local Fire Service.
From April 2024, all newly built residential buildings over 18 metres in height are required to include a second staircase. This change, introduced through amendments to Approved Document B of the Building Regulations, is designed to provide an additional evacuation route and improve access for firefighters. It applies to new builds only, and existing single-staircase buildings are not required to add a secondary staircase retrospectively; however, their fire risk assessments should consider whether the single staircase presents additional risk.
Call us today to discuss your requirements on 0117 978 0775 or get in touch for a NO OBLIGATION consultation and quotation
Residential Personal Emergency Evacuation Plans (Residential PEEPs)
Following major updates to UK fire safety regulations, as of 6 April 2026, building owners and managers face strict new obligations to protect vulnerable residents. If a building contains two or more sets of domestic premises that are at least 18 metres above ground level (or have at least seven storeys), or are more than 11 metres in height but only where they have simultaneous evacuation strategies in place, the responsible person has an explicit legal duty to manage evacuation plans for disabled or impaired occupants.
A Personal Emergency Evacuation Plan is a bespoke, person-centred plan designed to support those who cannot independently or safely escape a building during a fire. This includes residents with physical disabilities, sensory impairments or cognitive difficulties.
Under current legislation, the building’s Responsible Person must actively invite all residents to declare if they or anyone in their household would require assistance to evacuate the building in an emergency. This must be a direct, documented request. If the resident would like help, you must work with them to create a person-centred fire risk assessment and co-design a tailored resident PEEP.
Once complete, a copy of each Residential PEEP must be placed in the building’s secure information box. This immediately tells the Fire and Rescue crews who needs rescue, where they are located, and how to assist them. The Responsible Person must also share evacuation information with the local Fire and Rescue service, in accordance with resident consent and GDPR.
What Is A Fire Risk Assessment?
A Fire Risk Assessment is a necessary part of building management. This considers potential fire hazards and all of the considerations you should make to keep a property safe.
Therefore, whenever any changes are made to a block of flats or the overall fire risk, a new Fire Risk Assessment should be completed.
A Fire Risk Assessment typically covers:
- Identifying and recording fire hazards,
- Identifying and recording those at risk,
- Evaluating the findings of a fire risk assessment and addressing any fire hazards,
- Training people on fire safety practices and ensuring that there is a responsible person,
- Making a record of the process and reviewing it frequently.
Fire risk assessors and building managers need to be aware of BS 9991:2024, the updated British Standard for fire safety in residential buildings, which came into force in November 2024. It replaces the 2015 edition and introduces revised guidance on single-staircase building height limits, evacuation lift design, smoke ventilation, and the specific fire safety needs of vulnerable occupants.
Compliance with BS 9991:2024 is not a legal requirement in itself, but it represents recognised best practice, taken into account by regulators and courts when assessing whether a duty holder has met their obligations.
What Fire Safety Systems and Equipment Must A Flat Have?
As a landlord or building owner, you must keep shared spaces safe from fire risk. Therefore, emergency exit routes must be checked, and mains-connected fire detection systems installed.
In the UK, a landlord must provide a working smoke alarm on every storey used as living accommodation and a carbon monoxide alarm in any room with a fixed combustion appliance.
The Importance Of Testing and Maintenance Of Fire Safety Equipment
Regularly testing and maintaining fire safety equipment is a legal obligation and critical for life-saving. You must ensure that the equipment installed in your premises is capable of detecting a fire or eliminating fire hazards.
Under Article 17 of the Regulatory Reform (Fire Safety) Order 2005, the “Responsible Person” has a strict, absolute legal duty to ensure that all fire safety facilities, equipment and devices are maintained to an efficient state, in efficient working order, and in good repair. Failing to maintain these can result in criminal prosecution, heavy fines, or imprisonment.
Building owners and managers involved in construction, refurbishment, or replacement of fire safety materials should be aware that the UK has withdrawn the BS 476 national fire testing classification.
Therefore, from March 2025, all fire safety materials and products must be assessed under the European standard BS EN 13501. This standard provides more comprehensive and consistent classifications across a broader range of fire types. Any specifications or procurement decisions that still reference BS 476 should be reviewed and updated accordingly.
What Guidance Does Bristol City Council Offer For Flats?
More specifically, Bristol City is home to many blocks of flats, and the Bristol City Council provides basic guidance on the fire precautions required in privately rented properties in the area under its authority.
Are There Fire Safety Regulations For HMOs?
With an estimated 12,559 HMOs in Bristol in 2018, and that number has likely increased over the years, landlords and property owners in Bristol must be aware of the strict fire safety regulations they must meet.
The Housing Act 2004 sets minimum fire safety standards and allows local councils to license and inspect HMOs. The Regulatory Reform (Fire Safety) Order 2005 requires a responsible person, typically the landlord or property manager, to carry out a written fire risk assessment, minimise fire risks and maintain common areas. The Fire Safety (England) Regulations 2022 also place extra duties on landlords of multi-storey buildings to provide tenants with evacuation route information and fire door details.
In Houses in Multiple Occupation (HMOs), the fire risk and number of occupants is typically higher. Therefore, they face stricter legal requirements. HMOs should have mains-powered, interlinked smoke and heat detectors fitted throughout the property, as well as self-closing fire doors on all bedrooms, communal rooms, and along the escape routes. Landlords are also legally required to provide appropriate, wall-mounted fire extinguishers and a fire blanket in a communal kitchen.
Get in Touch With Our Expert Team Today
ELECSEC, specialises in the design, installation and maintenance of a wide range of fire alarms, and can give you advice on the systems you need to remain compliant. To speak to one of our experts, get in touch today.