ammended ld3,2,1 alarm

BS 5839:6 Fire Alarm Categories Explained

This article provides an introduction to BS 5839:6 and outlines the fire detection grading system and categories included in the standard. It is intended for informational purposes and should not replace reading the full standard.

Elecsec supply and install Fire and Security systems across Bristol and the South West, they can design and tailor the system to your exact specification to improve your properties safety and security needs.

What is BS 5839:6 and Why is it Important?

BS 5839-6 is a British standard that sets out recommendations for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises. The grading system defines the level of protection required, specifying the type of alarm system, the control and indicating equipment and also the areas that need coverage.
Grades range from Grade A (the highest level, with a full system including detectors, sounders, and a control panel) to Grade F (simpler, standalone battery-operated detectors).

Higher grades are typically required for larger homes or higher-risk dwellings, while lower grades suit smaller or lower-risk properties. This system helps ensure the appropriate level of fire safety, balancing risk, cost and practicality for different types of properties.

Why Compliance Matters

Meeting the requirements of BS 5839:6 is essential for ensuring safety in residential properties.
  • The majority of fire-related fatalities and injuries happen in homes, with around 80% occurring in domestic settings.
  • Research shows a clear reduction in fatalities when smoke detectors are installed. The risk of death in a fire is estimated to be two to three times higher without a detection system in place.
  • Because of this, building regulations mandate the installation of automatic fire detection systems in newly built houses, flats and maisonettes.
  • For existing houses in multiple occupation (HMOs), the relevant enforcing authority typically requires the installation of an automatic fire detection and alarm system.
  • BS 5839:6 is necessary because BS 5839:1 does not provide recommendations for domestic smoke alarms or account for the unique design considerations required for fire detection and alarm systems in homes.
This standard helps ensure that fire detection measures are appropriately designed to meet the specific needs of residential properties, improving safety for occupants.

What Properties Are Covered

Applicable Properties

  • Bungalows
  • Multi-storey houses
  • Individual flats and maisonettes
  • Sheltered housing
  • Houses providing NHS-supported living
  • Houses divided into multiple single-family dwelling units
  • Hostels

Non-Applicable Properties

  • Caravans
  • Mobile homes
  • Boats (except permanently moored houseboats)
  • Communal areas of purpose-built sheltered housing, blocks of flats, or maisonettes
  • Premises used for non-residential purposes (e.g. small shops, small factories)
  • Mansions

Arrange a Free Site Survey

Ensure the safety and security of your home or business with our cutting-edge fire and security solutions. Act now to safeguard your premises with our advanced CCTV systems, fire alarms, and 24/7 monitoring services.

Contact us today on 0117 978 0775 and speak to our expert team for a quote.

The BS5839:6 Fire Detection Grading Systems

The fire detection grades outline different combinations of Fire Detection and Control/Indicating Equipment (CIE) tailored for various domestic property requirements. The system for your property will fall into one of the categories below, depending on specific needs.
Grade A This is a comprehensive Fire Detection and Alarm (FD&A) system, including Control and Indicating Equipment (CIE) that meets BSEN54-2 and PSU equipment conforming to BSEN54-4. The installation follows all recommendations from sections 1 to 4 of BS5839:1.
Grade B This FD&A system consists of fire detectors (excluding smoke and heat alarms), fire alarm sounders, and CIE. The system either conforms to the Grade A requirements or complies with “Annex C” of BS5839:6.
Grade C This setup includes fire detectors and alarm sounders, which may be combined as smoke alarms, linked to a shared power supply, consisting of mains power and a standby supply, with centralised control equipment.
Grade D1 This configuration uses one or more mains-powered smoke alarms, each with a tamper-proof standby power supply, typically a battery or set of batteries.
Grade D2 Similar to Grade D1, this system also uses one or more mains-powered smoke alarms, but each comes with a user-replaceable battery or batteries as the standby supply.
Grade E This system consists of one or more mains-powered smoke alarms without a standby power supply. Optionally, it may include heat alarms, with or without a standby power source.
Grade F This setup involves one or more battery-powered smoke alarms, each with its integral standby power source. Heat alarms may also be included, which are typically battery-powered as well.

Interlinking Requirements for Grades D, E, and F

If more than one smoke alarm is installed, they generally need to be interlinked. Any heat alarms should also be connected to the smoke alarms.
For most residential properties in the UK, Grades D and F are the most commonly used, with some exceptions. While it’s possible to install a mixed-grade system, this should only be done after a clear risk assessment and in alignment with Building Regulations and relevant enforcement authorities. For example, a Grade A Category LD2 system could be installed in communal areas of a House in Multiple Occupation (HMO), while each residential unit might have its own Grade D1 Category LD1 system.

BS5839:6 System Categories – Areas That Should Be Protected

The system categories represent different levels of coverage required depending on the fire risk within specific areas of a property. They outline the degree of protection a fire detection system offers. The categories also provide guidance on the number and placement of alarms, which can impact the speed at which a fire is detected. In general, the higher the category, the more extensive the protection.
According to the standard, the level of protection provided should be appropriate to the fire risk present. The fire risk in various areas of a property is assessed based on the frequency of previous incidents. For example, 54% of reported fires have originated in the kitchen, making it a higher-risk area compared to the bathroom, which accounts for only 2% of fires.

Life Protection Systems – Order of Protection

The categorisation of fire protection systems reflects varying levels of coverage based on the fire risks within different areas of a property. These categories outline the level of protection provided by the fire detection system, which can influence the speed at which a fire is detected. As the category increases, the system generally provides a higher level of protection.

Protection Categories

LD3 Fire Alarm

Minimum Protection This level requires detectors to be installed in all circulation spaces forming part of the escape routes from the dwelling. These spaces include:
  • Hallways
  • Landings

LD2 Fire Alarm

Medium Protection This category includes detectors in all circulation spaces that form part of the escape routes, as well as in areas presenting a higher fire risk to occupants. These areas may include:
  • Hallways
  • Landings
  • Living rooms
  • Kitchens

LD1 Fire Alarm

Maximum Protection This level provides detectors in all areas where a fire could potentially start. This includes:
  • Hallways
  • Landings
  • Living rooms
  • Kitchens
  • Bedrooms
  • Airing cupboards
  • Meter cupboards

Arrange a Free Site Survey

Ensure the safety and security of your home or business with our cutting-edge fire and security solutions. Act now to safeguard your premises with our advanced CCTV systems, fire alarms, and 24/7 monitoring services. Our expert team is dedicated to providing you with peace of mind, knowing that your property is in good hands.
Contact us today to learn more about our services and how we can help you prevent the unthinkable. Protect what matters most – because your safety is our top priority.

Specific Guidance

The legal requirements for fire detection systems depend on the age and use of the dwelling, as building standards and regulations have evolved over time.

Rented Home Protection

Grade D1 / LD2D – New Build or Existing
This system comprises one or more mains-powered detectors with a tamper-proof backup power supply, typically using batteries.
Note D:
Heat detectors should be installed in every kitchen.
A smoke detector should be placed in the principal habitable room. If multiple rooms could serve as the principal habitable room, a smoke detector should be installed in each of them.

Owner-Occupied Home Protection

Grade D2 / LD2D – New Build (2-3 Storeys)
This system involves mains-powered detectors, each with an integral user-replaceable battery or batteries as a backup power source.
Note D:
Heat detectors should be installed in every kitchen.
A smoke detector should be placed in the principal habitable room. If multiple rooms could serve as the principal habitable room, a smoke detector should be installed in each of them.

Sheltered Housing – Existing Property Protection

Individual Dwellings: Grade D2, Category LD2Q
Communal Areas: Grade A, Category L4/L5
Note Q:
If sheltered housing is upgraded, rewired, or if smoke alarms are replaced, a Grade D (D1 or D2) system should be installed.

Sheltered Housing – New or Materially Altered Property Protection

Grade D1, LD1J
Note J:
Detectors may be omitted from roof voids unless there are specific significant fire hazards, such as gas boilers or electrical equipment for photovoltaic systems.

House of Multiple Occupancy (HMO) – Existing Property Protection (1-2 Storeys)

Grade D1, LD2D
Note D:
Heat detectors should be installed in every kitchen.
A smoke detector should be installed in the principal habitable room. Where multiple rooms might be used as the principal habitable room, a smoke detector should be installed in each of these rooms.

Examples of Fire Detection Systems in Various Property Types

It is crucial to conduct a fire risk assessment to determine the specific risks for your property. Below are some general recommendations for fire detection systems in different dwelling types:

HMO (Up to Two Storeys with No Floor Greater Than 200m²): Grade D1, Category LD1 throughout.


HMO (Each Dwelling Comprises a Single Room): Mixed system: Grade A, Category LD2 in common areas, in line with BS5839-1:2017, Category L2, with connected heat detectors in bedsits with cooking facilities. Grade D1, Category LD1 in each individual bedsit (not connected to the communal system) to protect sleeping occupants.


HMO (Each Dwelling Comprises Two or More Rooms): Mixed system: Grade A, Category LD2 in common areas, in line with BS5839-1:2017, Category L2. Additionally, Grade D1, Category LD2 in the dwelling itself (not connected to the communal system) to protect sleeping occupants.

Two-Storey House Converted to Self-Contained Flats (Pre-1991 Building Regulations): Mixed system: Grade D1, Category LD2 in common areas, and a heat detector in each flat (room/lobby opening onto escape route) connected to the communal system. Additionally, Grade D1, Category LD3 in each flat (not connected to the communal system) to protect sleeping occupants.

Three to Six-Storey House Converted to Self-Contained Flats (Pre-1991 Building Regulations): Mixed system: Grade A, Category LD2 in common areas, in line with BS5839-1:2017, Category L2, with connected heat detectors in each flat (connected to the communal system). Additionally, Grade D1, Category LD3 in each flat (not connected to the communal system) to protect sleeping occupants.

Single Household with Fewer Than Four Storeys: Grade D1, Category LD2, including cellar protection.
Single Household with Four or More Storeys:

Grade A, Category LD1, including cellar protection.

Flat in Multiple Occupation (FMO) – Single Storey: Grade D1, Category LD2, with an additional heat detector in the kitchen and, depending on risk, a shared living room.

By following these guidelines and conducting a proper fire risk assessment, you can ensure that the fire protection system in your dwelling is suitable for the specific risks and requirements of the property.

Get In Touch Today

At ELECSEC, we are the leading independent provider of Fire and Security in Bristol. We will work with you to carry out an honest assessment of your current system and recommend using our knowledge – the best fire and security system for your requirements. We will also ensure that you are fully compliant with any relevant legal obligations. Get in touch to arrange for a free quote.

For all your Fire and Security needs contact our expert team today on 0117 978 0775.
Lastly, to keep up with all of our news and to find some inspiration, you can follow us on Instagram and Facebook.